Perfused Organs-on-a-Chip integrated with TEER measurement technique: A novel approach towards studying non-targeted drug induced organ toxicity

Projektbeschreibung

Mikrofluidisches Organ-on-a-Chip-System zur Verbesserung der vorklinischen Wirkstoffentwicklung

Das EU-finanzierte Projekt PORTable STaNDOuTs hat sich zum Ziel gesetzt, mikrofluidische Organ-on-a-Chip-Systeme, die mit Elektroden für TEER-Messungen (Messungen des transepithelialen elektrischen Widerstands) integriert sind, zu entwickeln, um die derzeitigen zeit- und kostenintensiven vorklinischen Verfahren im Wirkstoffentwicklungsprozess zu ersetzen. TEER-Messungen sind schnell und nichtinvasiv. Sie zeigen die Integrität der Zellmembranbarriere verschiedener Organe an, die für die Homöostase im menschlichen Körper notwendig sind. Ziel ist es, ein perfundiertes Gerät mit drei Kammern herzustellen, einer für den Darm, einer für die Leber und einer für die Nieren. Diese sollen unabhängig mit Elektroden zur Messung von TEER-Werten ausgerüstet sein, um die Integrität der Zellmembranbarrieren in jeder Organkammer feststellen zu können. Die entwickelte Technologie wird anschließend nach ihrer Fähigkeit zur Untersuchung von wirkstoffinduzierter Nephrotoxizität validiert.

Ziel

PORTable STaNDOuTs aims to develop a multiple Organs-on-a-Chip (MOOC) microfluidic device integrated with electrodes for carrying out Transepithelial electrical resistance (TEER) measurements. The key motivation for adopting such an approach is to develop a rapid, versatile and cost-effective prototype with ability for real-time monitoring to replace the conventional long and cost-ineffective preclinical procedures involved in the drug development process. On administration of an oral pharmaceutical drug, major organs that are involved in the absorption and metabolism of drug are intestine and liver. The drug is then distributed to different target organs such as brain, heart, lung, etc. Finally, the drug metabolites are eliminated from the human system with the help of kidney. Additionally, it has also been found that certain drug metabolites produced by the liver cause non-target drug induced organ toxicity. TEER measurement is a rapid and non-invasive technique for the real-time detection of pathophysiology. TEER indicates the integrity of the cell membrane barrier of different organs that is necessary for maintaining homeostasis within the human body. In view of this, we intend to fabricate a physiologically-mimicking perfused intestine-liver-kidney microfluidic chip with provision for carrying out in-chip TEER measurements. The device will be designed to consist of three compartments for organs namely, intestine, liver and kidney, independently equipped with electrodes for measuring TEER values to detect the integrity of cell membrane barriers in each organ compartment. The developed device will be then subsequently validated for its ability to study drug-induced nephrotoxity. Furthermore, the device will also be made versatile to incorporate other organs of interest to study non-target organ toxicity. Thus, the developed MOOC microfluidic device will surely boost the drug development process that will successively improve the health security of the society.

Wissenschaftliches Gebiet

CORDIS klassifiziert Projekte mit EuroSciVoc, einer mehrsprachigen Taxonomie der Wissenschaftsbereiche, durch einen halbautomatischen Prozess, der auf Verfahren der Verarbeitung natürlicher Sprache beruht.

Koordinator

CHERRY BIOTECH
Netto-EU-Beitrag
€ 184 707,84
Adresse
2EME ETAGE, HALLS A-B ET C14 RUE DE LA BEAUNE
93100 Montreuil
Frankreich

Auf der Karte ansehen

KMU

Die Organisation definierte sich zum Zeitpunkt der Unterzeichnung der Finanzhilfevereinbarung selbst als KMU (Kleine und mittlere Unternehmen).

Ja
Region
Ile-de-France Ile-de-France Seine-Saint-Denis
Aktivitätstyp
Private for-profit entities (excluding Higher or Secondary Education Establishments)
Links
Gesamtkosten
€ 184 707,84