Rezultaty
Analysis of the “status quo” of industrial cooling based on solar heat at the demo sites
Analysis of the “status quo” of industrial cooling based on solar heat at the demo sites. This report will summarize the analysis of the industrial processes for the demo sites, in terms of overall cooling demand, working boundary conditions (e.g. distribution temperatures, flow rates, power consumption) as well as dynamic profiles at demand side.
Experimental characterization of the hybrid heat pump moduleExperimental characterization of the hybrid heat pump module. Experimental characterization of the hybrid heat pump module under real operating conditions, to draw a performance map. Testing under off-design severe working conditions and experimental validation of different implemented management strategies.
HyCool project websiteHyCool project website. The website will include news, information, and public deliverables produced by the project.
Validation of the developed model for lab-scale experiments, 50kWh test facility of T 3.4 as well as for the demonstration sitesValidation of the developed model for lab-scale experiments, 50kWh test facility of T 3.4 as well as for the demonstration sites. The aim of the validation is to demonstrate that the model developed is capable of predicting the real-scale behaviour of the different adsorber materials sufficiently to serve as a future guide in the choice of adsorbir.
Requirements: context of application and industrial processes classificationRequirements: context of application and industrial processes classification. This will integrate a synthetic analysis of all the available tools and propose a method/procedure to enhance it and increase their value by applying them in operational contexts. The final method will make it possible to determine which kinds of process and industries can use the system to be developed.
Design review of the hybrid heat pumpDesign review of the hybrid heat pump. Final design review of the full-scale hybrid heat pump according to the obtained experimental outcomes.
HyCool public communication materialsHyCool public communication materials, consisting of a project poster, brochure, annual newsletter and project video during the final project year.
VR/AR Intelligent Training Systems based on a Geolocated BIM models.Technical and market review codes studies, national and European certification frameworks
Technical and market review codes studies, national and European certification frameworks. This report will set specifications to meet basic requirements in compliance with regulations affecting the system designed, managed and operated by HyCool. National regulatory conditions have a direct impact on the post project market uptake and future certification strategy of the different HyCool products.
Workshop SeriesFirst design of the modular hybrid heat pump
First design of the modular hybrid heat pump. Design of the modular hybrid heat pump, with advanced performance in terms of power density and efficiency.
Market AnalysisA comprehensive Market Analysis of the system technologies for industrial processes, cooling and steam Applications.
Key Performance Indicators for the machine and the processes levelsDrawing of the hydraulic schematic
Drawing of the hydraulic schematic, specification of the system components, list of all sensor inputs and output signals, software interfaces as far as required.
Model capable of estimating the performance of a given adsorption chiller set-up and a given adsorber material for a given application scenarioModel capable of estimating the performance of a given adsorption chiller set-up and a given adsorber material for a given application scenario. A model of the global properties of the adsorber material in the different forms at different temperatures, pressures and relative humidities will be developed.
Business Models and PlansBusiness plans and models for successfully bringing HyCool results into the market.
Exact measuring protocol for different adsorber materials. A minimal set of measurement and precise measurement protocols will be developed to be able to consistently and reliably estimate the full set of properties necessary.
Social Impact AssessmentSocial Impact Assessment The report will be addressing the evaluation of the impacts and the identification of the benefits that can be quantified thanks to the HyCool project
Final report on project managementFinal report on project management This report will summarize the following aspects A timely review of the scheduled milestones and deliverables will allow an efficient project implementation as well as concrete options for adjustments of management procedures compliance with the provisions of the EC Grant Agreement finances and monitors each partners costs and all administrative matters
Report on the contribution to standardsInterim report on project management
Interim report on project management. This report will summarize the following aspects: A timely review of the scheduled milestones and deliverables will allow an efficient project implementation as well as concrete options for adjustments of management procedures, compliance with the provisions of the EC (Grant Agreement), finances and monitors each partner’s costs and all administrative matters.
Report of field demonstration and optimizationReport of field demonstration and optimization This report will include the operation of the control algorithm operation priorities tested and optimized for the installed units in the field the heat pump performance under actual operating conditions as well as the solar gain and utilization
Project Management PlanDetailed Project Management Plan with a Gantt chart and a Work Breakdown Structure (WBS). It should include a schedule per task, responsible partner related subtasks, related deliverables, and dependencies on other tasks.
Evaluation of long-term behaviour and possible degradation of the materials in the adsorption chillerEvaluation of longterm behaviour and possible degradation of the materials in the adsorption chiller The main focus lies on cracking as well as signs for chemical deterioration eg corrosion as well as any evolution of specific surface area and the adsorption behaviour Based on these results it will be estimated whether any special care has to be taken to ensure the long term performance of the adsoption chillers
Interim first year report on project managementInterim first year report on project management. This report will summarize the following aspects: A timely review of the scheduled milestones and deliverables will allow an efficient project implementation as well as concrete options for adjustments of management procedures, compliance with the provisions of the EC (Grant Agreement), finances and monitors each partner’s costs and all administrative matters.
Report on the standardization landscape and applicable standardsManufacturing and commissioning of the full-scale hybrid heat pump. Manufacturing of each component and realization of the full-scale hybrid heat pump for testing in the demo sites. Commissioning at the FAH premise to verify hydraulic, mechanical and electrical functionalities.
Publikacje
Autorzy:
Valeria Palomba; Giuseppe E. Dino; Steffen Kühnert; Davide La Rosa; Andrea Frazzica
Opublikowane w:
info:cnr-pdr/source/autori:Valeria Palomba, Giuseppe E. Dino, Steffen Kühnert, Davide La Rosa, Andrea Frazzica/congresso_nome:Eurosun2020/congresso_luogo:/congresso_data:1-3%2F09%2F2020/anno:2020/pagina_da:/pagina_a:/intervallo_pagine:, Numer 14, 2020
Wydawca:
Eurosun2020
Autorzy:
Valeria Palomba, Andrea Frazzica, Steffen Kühnert, André Große
Opublikowane w:
Proceedings of EuroSun 2018, 2018, Strona(/y) 1-8, ISBN 978-3-9820408-0-6
Wydawca:
International Solar Energy Society
DOI:
10.18086/eurosun2018.04.01
Autorzy:
Serena Scotton; Régis Decorme; Marco Calderoni; Sergio Valentino Costa; Alessandra Cuneo; Andrea Frazzica; Stefano Barberis; Federica Fuligni; Francesco Martinelli; Fabio Magrassi
Opublikowane w:
info:cnr-pdr/source/autori:Serena Scotton, Régis Decorme, Marco Calderoni, Sergio Valentino Costa, Alessandra Cuneo, Andrea Frazzica, Stefano Barberis, Federica Fuligni, Francesco Martinelli, Fabio Magrassi/congresso_nome:Sustainable Places 2019/congresso_luogo:Cagliari (Italia)/congresso_data:5-7%2F06%2F2019/anno:2019/pagina_da:/pagina_a:/intervallo_pagine:, Numer 62, 2019
Wydawca:
Sustainable Places 2019
Autorzy:
Emanuele Piccoli; Vincenza Brancato; Andrea Frazzica; François Maréchal; Sandra Galmarini
Opublikowane w:
Thermal science and engineering progress, Numer 37, 2022, ISSN 2451-9049
Wydawca:
Elsevier
DOI:
10.5281/zenodo.7553632
Autorzy:
Giuseppe E. Dino; Valeria Palomba; Eliza Nowak; Andrea Frazzica
Opublikowane w:
info:cnr-pdr/source/autori:Giuseppe E. Dino (a), Valeria Palomba (a), Eliza Nowak (b), Andrea Frazzica (a)/titolo:Experimental characterization of an innovative hybrid thermal-electric chiller for industrial cooling and refrigeration application/doi:10.1016%2Fj.apenergy.2020.116098/rivista:Applied energy/anno:2021/pagina_da:/pagina_a:/intervallo_pagine:/volume:281, Numer 32, 2020, ISSN 2574-0962
Wydawca:
Applied Energy
DOI:
10.1016/j.apenergy.2020.116098
Autorzy:
Uli Jakob (*1) and Falko Kiedaisch (*1)
*1: Dr. Jakob energy research GmbH & Co. KG (JER), Pestalozzistr. 3, 71384 Weinstadt (Germany)
Opublikowane w:
ISES Solar World Congress 2019, Numer SWC2019, 2019, Strona(/y) 2542-2551
Wydawca:
ISES Solar World Congress 2019
Wyszukiwanie danych OpenAIRE...
Podczas wyszukiwania danych OpenAIRE wystąpił błąd
Brak wyników