Periodic Reporting for period 2 - MELODIC (Molecule for low diffusion TPCs for rare event searches)
Okres sprawozdawczy: 2018-09-18 do 2019-09-17
The discovery of the neutrino as Majorana particle means that it is indistinguishable from its antiparticle. This will have profound implications for cosmology, as Majorana neutrinos violate lepton number and could explain matter-antimatter difference in the Universe.
Currently, the most sensitive experimental method to establish that neutrinos are Majorana particles is the search for neutrinoless double beta decay (0nubb). The NEXT experiment is seeking for this decay in a high pressure xenon gas (HPGXe) time projection chamber (TPC) with electroluminescent (EL) amplification. This technology is one of the most promising as it can uniquely image the track of the two electrons emitted in a bb0nu event, together with high energy resolution. However, the current imaging performance is limited by the diffusion of the ionization electrons during drift. The goal of the Marie Sklodowska Curie project MELODIC is to reduce this diffusion by a factor 3 at 10 bar pressure by adding additives like He or CH4 to the pure xenon gas. This could enhance the sensitivity of the HPGXe-EL technology to the bb0nu decay by a factor 2 at 15 bar pressure.
The main goal of the project has been achieved. We have demonstrated experimentally that adding 15% of Helium to the pure xenon can reduce the transverse diffusion of the pure xenon configuration a factor of 3 at a total pressure of 10 bar.
Since my return to IFIC, (31/10/2018-20/10/2019) I constructed the DEMO++ detector together with the technical team and my PhD student. We operated DEMO++ with pure xenon and with the mixtures and finally achieved the main goal of Melodic
which is the measurement of the transverse diffusion. We measured that the addition of 15 % of Helium to pure xenon decreases the transverse diffusion a factor of 3 with respect to the pure xenon configuration. This is the first direct measurement
of the effect of using helium mixtures to reduce the transverse diffusion in a high pressure xenon gas time projection chamber with electroluminescent amplification.
The expected final result of the MELODIC project is to improve the HPGXe-EL technology to substantially enhance the expected sensitivity to the 0nubb decay. The increase on the expected sensitivity for a tonne-scale is of a factor two, increasing considerably with exposure. MELODIC has demonstrated that the helium mixtures can reduced a factor of 3 the transverse diffusion with respect to pure xenon. The work performed in MELODIC will be continue by the N. López-March, which is currently the coordinator of the DEMO++ experiment to explore further gas mixtures to reduce the diffusion of the electrons and hence improve the imaging capability of the NEXT technology.