Skip to main content
European Commission logo
Deutsch Deutsch
CORDIS - Forschungsergebnisse der EU
CORDIS
CORDIS Web 30th anniversary CORDIS Web 30th anniversary
Inhalt archiviert am 2024-06-18

Multiscale investigation of drug - implantable cardioverter defibrillator interactions for antiarrhythmic therapy

Ziel

"The implantable-cardioverter defibrillator (ICD) is an effective treatment for terminating life threatening ventricular arrhythmias or fibrillations. However, as ICD only serves to terminate tachyarrhythmias and provide pacing support for bradyarrhythmias, concomitant antiarrhythmic drug therapy is common and leads to interactions with the ICD.

Direct drug-ICD interactions include alterations of the pacing threshold (minimum energy needed to achieve a reliable and consistent electrical activation of the heart) and of the defibrillation threshold (the lowest energy level that results in successful defibrillation).

Besides, anti-arrhythmic drugs which work by interfering with ion channel activity, may lead to cardio toxicity and then to ventricular arrhythmias, resulting in increased ICD therapies. Antiarrhythmic drugs can also lead to morphological changes present in the electrogram (EGM) interfering with the ICD function by failures of sensing ventricular events or arrhythmia classification.

The underlying mechanisms of ICD/drug interactions are poorly understood as well as how an ischemic substrate, present in most of the ICD patients, would affect those interactions. Indeed, ICDs are mainly used by patients with a history of previous myocardial infarction (MI) and left ventricle ejection fraction (LVEF) less than 35%.
In this framework, this proposal aims at providing a new level of understanding of the interactions between ICD and investigating biomarkers from the electrocardiographic signal (ECG) to predict adverse drug-ICD interactions in ischemic and control patients. The approach will be a combination of modelling and simulation at human tissue level and ECG signal processing. This multidisciplinary project will include direct contact with clinicians to analyse ECG data from ICD patients and pharmacological companies to study the possible cardiotoxicity of class I and III drugs in control and ischemia conditions."

Aufforderung zur Vorschlagseinreichung

FP7-PEOPLE-2011-IEF
Andere Projekte für diesen Aufruf anzeigen

Koordinator

THE CHANCELLOR, MASTERS AND SCHOLARS OF THE UNIVERSITY OF OXFORD
EU-Beitrag
€ 200 371,80
Adresse
WELLINGTON SQUARE UNIVERSITY OFFICES
OX1 2JD Oxford
Vereinigtes Königreich

Auf der Karte ansehen

Region
South East (England) Berkshire, Buckinghamshire and Oxfordshire Oxfordshire
Aktivitätstyp
Higher or Secondary Education Establishments
Kontakt Verwaltung
Gill Wells (Ms.)
Links
Gesamtkosten
Keine Daten